This glossary contains many useful terms and definitions. For easier browsing you can view our Photo Glossary, which has photographs of common roofing sites and problems, or you can browse the entire glossary by our alphabetical listing. |
|
|
Eave Height: the vertical dimension from finished grade to the eave. ECH: polyepichlorohydrin, commonly referred to as epichlorohydrin. (See Epichlorohydrin.) Edge Stripping: membrane flashing strips cut to specific widths used to seal/flash perimeter edge metal and the roof membrane. Edge Venting: the practice of providing regularly spaced or continuously protected (e.g., louvered) openings along a roof edge or perimeter, used as part of a ventilation system to dissipate heat and moisture vapor. Efflorescence: the formulation of crystalline deposits, generally whitish in color, on the surface of stone, brick, concrete, or other masonry surface when moisture moves through and evaporates on the masonry. May also be caused by free alkalies leached from mortar, grout, or adjacent concrete. Elasticity: the property of matter by virtue of which it tends to return to its original size and shape after removal of a stress or force which caused a deformation. Elastomer: natural or synthetic material which, at room temperature, can be stretched under low stress and, upon immediate release of the stress or force, will return quickly to its approximate original dimensions. Elastomeric: the elastic, rubber-like properties of a material that will stretch when pulled and will return relatively quickly to its original shape when released. Elastomeric Coating: a coating system which, when fully cured, is capable of being stretched at least twice its original length (100% elongation) and recovering to its original dimensions. Elongation: the ability of a material (e.g., roofing membrane) to be
stretched by the application of a force. Embrittlement: the loss of flexibility or elasticity of a material. The transition of a flexible material to a brittle state. Emulsion: a dispersion of fine particles or globules in a liquid. (See Asphalt Emulsion and Bitumen Emulsion.) End Lap: the distance of overlap where one ply, panel, or piece extends beyond the end of the immediately adjacent underlying ply, panel, or piece. Envelope (Bitumen-Stop): a continuous edge seal formed at the perimeter and at penetrations by extending the base sheet or one ply of felt beyond the edge of the membrane field plies. After all overlying field plies or insulation are in place, the extended ply is turned back onto the membrane and adhered. The envelope is intended to prevent bitumen seepage from the edge of the membrane. Epichlorohydrin (ECH): a synthetic rubber including two epichlorohydrin based elastomers. It is similar to and compatible with EPDM. ECH is typically used in lieu of EPDM when enhanced resistance to animal fat or other oils is needed. Epoxy: a class of synthetic, thermosetting resins that produce tough, hard, chemical-resistant coatings and adhesives. Equilibrium Moisture Content (EMC): (1) the moisture content of a material stabilized at a given temperature and relative humidity, expressed as percent moisture by weight; (2) the typical moisture content of a material in any given geographical area. Equiviscous Temperature (EVT): the temperature at which a bitumen attains the proper viscosity for built-up membrane application. Equiviscous Temperature (EVT) Application Range: the recommended bitumen application temperature range. The range is approximately 25°F (14°C) above or below the EVT, thus giving a range of approximately 50°F (28°C). The EVT Range Temperature is measured in the mop cart or mechanical spreader just prior to application of the bitumen to the substrate. Equiviscous Temperature (EVT) for Asphalt: the recommended EVT for roofing asphalt (ASTM D312, Type I, II, III, or IV) is as follows:
Mechanical Spreader Application: the temperature at which the asphalt's apparent viscosity is 75 centipoise (0.075 Pa.s). Note: If there are simultaneous mop and mechanical spreader applications, in order to avoid the use of two kettles, the EVT for mechanical spreader application may be used for both application techniques. Equiviscous Temperature (EVT) for Coal Tar: the recommended EVT for roofing coal tar (ASTM D 450, Type I or III) is the temperature at which the coal tar's apparent viscosity is 25 centipoise (0.025 Pas). Ethylene Interpolymers (EIP): a group of thermoplastic compounds generally based on PVC polymers from which certain single-ply roofing membranes can be formulated. Ethylene Propylene Diene Terpolymer (EPDM): designated nomenclature of ASTM for a terpolymer of ethylene, propylene, and a diene. EPDM material is a thermosetting synthetic elastomer. EVT: Equiviscous Temperature Exhaust Ventilation: air that is typically vented or exhausted from the roof cavity, typically through vents installed on the upslope portion of the roof. For example, with most steep-slope roof assemblies exhaust vents are typically located at or near the ridge. Exotherm: heat generated by a chemical reaction. Expansion Cleat: a cleat designed to handle thermal movement of the metal roof panels. Expansion Joint: a structural separation between two building elements that allows free movement between the elements without damage to the roofing or waterproofing system. |
|
|
Factory Mutual Research Corporation (FMRC): (commonly referred to as "FM") a research and testing organization that classifies roofing components and assemblies for their fire, traffic, impact (hail), weathering, and wind-uplift resistance for four major insurance companies in the United States. Factory Seam: a splice/seam made by the manufacturer during the assembly of sections of materials into large sheets. Fallback: a reduction in the softening point temperature of asphalt that occurs when asphalt is heated for pro-longed periods at elevated temperature. (See Softening Point Drift.) Fascia: a vertical or steeply sloped roof or trim located at the perimeter of a building. Typically, it is a border for the low-slope roof system that waterproofs the interior portions of the building. Fasteners: any of a wide variety of mechanical securement devices and assemblies, including nails, screws, cleats, clips, and bolts, which may be used to secure various components of a roof assembly. Felt: a flexible sheet manufactured by the interlocking of fibers through a combination of mechanical work, moisture, and heat. Roofing felts may be manufactured principally from wood pulp and vegetable fibers (organic felts), asbestos fibers (asbestos felts), glass fibers (fiberglass felts or ply sheet), or polyester fibers. Felt Machine (Felt Layer): a mechanical device used for applying bitumen and roofing felt or ply sheet simultaneously. Ferrule: a small metal sleeve placed inside a gutter at the top. A spike is nailed through the gutter into the fascia board to hold the gutter in place. The ferrule acts as a spacer in the gutter to maintain its original shape. Fiberglass Insulation: blanket or rigid board insulation, composed of glass fibers bound together with a binder, faced or unfaced, used to insulate roofs and walls. Rigid boards usually have an asphalt and kraft paper facer. Field of the Roof: the central or main portion of a roof, excluding the perimeter and flashing. Field Seam: a splice or seam made in the field (not factory) where overlapping sheets are joined together using an adhesive, splicing tape, or heat- or solvent-welding. Fishmouth: (also referred to as an Edge Wrinkle) (1) a half-cylindrical or half-conical shaped opening or void in a lapped edge or seam, usually caused by wrinkling or shifting of ply sheets during installation; (2) in shingles, a half-conical opening formed at a cut edge. Flaking: detachment of a uniform layer of a coating or surface material, usually related to internal movement, lack of adhesion, or passage of moisture. Flash Point: the lowest temperature of a liquid at which it gives off vapors sufficient to form an ignitable mixture with air near its surface. Flashing: components used to weatherproof or seal the roof system edges at perimeters, penetrations, walls, expansion joints, valley, drains, and other places where the roof covering is interrupted or terminated. For example, membrane base flashing covers the edge of the field membrane, and cap flashings or counterflashings shield the upper edges of the base flashing. Flashing Cement: as used by the roofing industry, an ASTM D 2822 Type II roof cement that is a trowelable mixture of solvent-based bitumen and mineral stabilizers that may include asbestos or other inorganic or organic fibers. Generally, flashing cement is characterized as vertical-grade, which indicates it is intended for use on vertical surfaces. (See Asphalt Roof Cement and Plastic Cement.) Flood (Pour) Coat: the surfacing layer of bitumen into which surfacing aggregate is embedded on an aggregate surfaced built-up roof. A flood coat is generally thicker and heavier than a glaze coat, and is applied at approximately 45-60 pounds per square (2-3 kilograms per meter). Fluid-Applied Elastomer: a liquid elastomeric material that cures after application to form a continuous waterproofing membrane. FM: see Factory Mutual Research Corporation. |